Operation Theatre Fumigator [OT Fumigator]
 
 
D4 Surgicals (India) Pvt. Ltd. is a Manufacturer and Exporter of Operation Theatre Fumigator. These OT Fumigators consume negligible power and virtually require no maintenance. D4 Surgicals (India) Pvt. Ltd. provides Operation Theatre Fumigator to suit the requirements of each and every medical profession. These Operation Theatre Fumigator are used in most of the Indian hospitals and Dispensaries. D4 Surgicals has also earned a good reputation from the international community as one of the best quality Operation Theatre Fumigator Manufacturer from India. While Manufacturing these Operation Theatre Fumigator best quality standards are followed.
 
 
     
  Operation Theatre Fumigator Manufacturer Get a Quote
     
Features:-    
  • Light Weight And Portable
  • Easy To Operate 
  • Virtually No Maintenance Required.
  • Negligible Power Consumption.
  • 100% Convenient
     
 
 
  TECHNICAL DATA  
     
Body
:
Fully Stainless Steel
Maximum Height
:

16 Inches

Outer Diameter
:
17 Inches.
Weight
:
9 Kgs (Appr.)
Electric Supply
:
230 50Hz. Single Phase A.C.
Connected Load
:
90 Watts
Power Consumption
:
0.150Kws / Hr.
Atomizing Cap.
:
30 - 35 ml / min
     
     
DISINFECTION PROCEDURE    
     
  • Unpack the equipment and check the functioning by plugging it into a 3 pin 5 Amps 230 V electrical socket
  • Ascertain the dos'age required for the room to be disinfected.
  • Place 'OT Fumigator' inside the operation theatre.
  • Pour in the formation & water into the dish from sides.
  • Close and seal all the windows, ventilators openings and the door of the place to be disinfected.
  • Plug in the unit's main cord into a 3 pin, 5 Amp, 230V, electrical Sockets with switch.
    Which must be provided outside the operation theatre or use automatic timer.
  • Switch on the 'OT Fumigator' and allow it to run for 30 minutes then switch it off.
  • Wait for 6 hours and open the room before re-using the room, exhaust remaining fumes if any by switching on the fan / exhaust of the window and airconditioner.
   
   
   
   
   
   
   
   
     